KOSA Filtration · Heat Exchangers
DTS Double Tubesheet Heat Exchanger — WFI / PW · ASME BPE
The King Lai DTS double-tubesheet heat exchanger is a shell-and-tube unit for pharmaceutical water systems that separates the product from the thermal medium with two tube sheets, so that any leakage escapes through the gap between them instead of entering the product stream.
KOSA supplies the King Lai DTS range to pharmaceutical and biopharmaceutical projects, with selection support against your duty, utilities and clean-utility loop design.
Introduction
The DTS series is applied to Water for Injection (WFI), Purified Water (PW) and other temperature-sensitive pharmaceutical processes, for heating or cooling duties. The unit is engineered to the requirements of ASME BPE, USP and cGMP. The outer tube sheet is in direct contact with the process fluid while the inner tube sheet interfaces with the thermal medium; in the rare event of a leak, fluid escapes through the gap between the two tube sheets, allowing immediate detection and preventing contamination of the product stream.
Features
- Double-tube sheet design: process fluid contacts the outer tube sheet and thermal medium the inner one; a leak escapes through the detection slots between the sheets.
- Zero dead-leg construction ensures complete drainage in both horizontal and vertical installation.
- SIP compliant, meeting pharmaceutical sterilization requirements in place.
- Orbital automatic welding plus advanced hydraulic expansion, with U-bend forming to the ASME BPE R-radius.
- Four installation orientations (0, 90, 180 and 270 degrees) on a mobile support frame, with integrated lifting rings.
Specifications
| Parameter | Value |
|---|---|
| Wetted parts | 316L stainless steel B p5 L002 |
| Non-wetted parts | 304 stainless steel B p5 L002 |
| O-rings | EPDM or VITON, FDA 21 CFR 177, USP Class VI B p5 L003 |
| Pressure | -1 to 10 bar B p5 L006 |
| Temperature | -10 to 200 °C B p5 L008 |
| Tube type | Seamless or welded B p5 L010 |
| Design standards | GB, ASME VIII, PED, TSG B p5 L012 |
| Tube inner surface | SF1 Ra <= 0.51 μm; SF4 Ra <= 0.38 μm B p5 L015 |
| Outer surface | Sandblasted or brushed B p5 L016 |
| Welding standards | SS-EN-ISO 15614-1, EN 287-1, EN 1418, ASME IX B p5 L018 |
| Insulation (shell side) | Rock wool or aluminum silicate B p5 L022 |
Data: King Lai catalog B p5. Confirm final selection against the manufacturer's datasheet.
Model range: DTS-2 and DTS-4 pass versions, shell diameter 73.0-168.3 mm, tube diameter 9.53 or 12.70 mm, heat-transfer area 0.20-4.98 m2, total length 1000, 1500 or 2000 mm; customization available upon client request. (Source: King Lai catalog B p6 L004-L069)
Frequently asked questions
How does a double-tubesheet design prevent cross-contamination?
In the King Lai DTS double-tubesheet heat exchanger, the outer tube sheet is in direct contact with the process fluid and the inner tube sheet with the thermal medium. In the rare event of a leak, fluid escapes through the gap between the two tube sheets, where it can be detected immediately instead of entering the product stream. (Source: King Lai catalog B p4 L017-L022)
What pressure and temperature range does the DTS handle?
The King Lai DTS double-tubesheet heat exchanger is rated from -1 to 10 bar and from -10 to 200 °C, with 316L stainless steel wetted parts, 304 non-wetted parts and EPDM or VITON O-rings rated to FDA 21 CFR 177 and USP Class VI. (Source: King Lai catalog B p5 L002-L008)
Which standards and welding processes are used?
The King Lai DTS double-tubesheet heat exchanger is built to GB, ASME VIII, PED and TSG, with welding to SS-EN-ISO 15614-1, EN 287-1, EN 1418 and ASME IX; tubes are joined to the tube sheets by orbital automatic welding and hydraulic expansion. (Source: King Lai catalog B p5 L012-L024)
Related reading
Related: point-of-use WFI heat exchanger · for aseptic shut-off on the same loop, see King Lai sterile diaphragm valves · Selection guide
Need a quote or full specification?
KOSA supplies King Lai DTS — send your duty, materials and quantity for a matched proposal.
Request a quote