King Lai mini Micro Heat Exchanger — UPW · 0–104 bar

The King Lai BioClean mini heat exchanger is a straight-tube unit for ultra-pure water and gas duty with a design pressure of 0–104 bar, a design temperature of 425 °C and a heat transfer area of 0.005 to 3.0 m².

KOSA supplies King Lai BioClean mini heat exchangers for point-of-use cooling and for semiconductor gas and UPW temperature control.

King Lai BioClean mini heat exchanger, straight tube body with tubesheet face and side nozzle
King Lai BioClean mini heat exchanger · mini · Source: King Lai catalog B p16 L003–L029, p17 L008–L029, p18 L001–L034

Last updated:

Introduction

The unit is engineered to ultra-pure standards for pharmaceutical point-of-use cooling of Water for Injection, and also serves semiconductor heating, cooling and condensation of gases or ultrapure water. A straight tube body without dead legs keeps flow uniform, and the optional double tubesheet design removes any risk of cross-contamination between product and utility.

Features

Specifications

ParameterValue
Metal material316L stainless steel, custom alloys on request B p16 L016
Non-metallic materialNone B p16 L017
Design pressure0–104 bar B p16 L018
Max working pressure, tube side≤ 8.3 MPa B p16 L019
Max working pressure, shell side≤ 5.5 MPa B p16 L021
Design temperature425 °C B p16 L022
Exchanger typeSingle tube sheet (straight tube) or double tubesheet (straight tube) B p16 L023
Design standardsGB, ASME, PED B p16 L024
Surface finishElectropolished to Ra ≤ 0.1 μm (EP) B p16 L025
Heat transfer area0.005–3.0 m² B p16 L026
ConnectionsNPT, Rc; tube side 1/4 in, shell side 1/4 in B p16 L027–L029
CertificatesEN10204 3.1 material certificate, roughness, pressure and helium leak reports B p17 L019–L022
CleaningCIP and COP B p17 L028–L029

Data: King Lai catalog B p16–p18. Confirm final selection against the manufacturer's datasheet.

How to choose

ConditionRecommended
When the utility must never contact the productChoose the double tubesheet design
When the space is tight and the duty is smallChoose the 0.005 m² end of the range
When the process runs at high pressureChoose the 104 bar design pressure rating

Frequently asked questions

What pressure and temperature can the King Lai BioClean mini heat exchanger take?

The King Lai BioClean mini heat exchanger is designed for 0–104 bar and 425 °C, with tube side working pressure up to 8.3 MPa and shell side up to 5.5 MPa. [B p16–p17]

What surface finish and area does the mini heat exchanger offer?

The King Lai BioClean mini heat exchanger is electropolished to Ra ≤ 0.1 μm and covers a heat transfer area of 0.005 to 3.0 m². [B p16–p17]

Which documents come with the mini heat exchanger?

The King Lai BioClean mini heat exchanger is supplied with an EN10204 3.1 material certificate, surface roughness reports, pressure test reports and helium leak test records. [B p16–p17]

Need a quote or full specification?

KOSA supplies King Lai mini — send your duty, materials and quantity for a matched proposal.

Request a quote

Request a Quote from KOSA

Tell us about your 316L stainless piping, filtration, valve or heat-exchanger requirements. The responsible KOSA specialist will get back to you with a quotation and technical proposal.